Influence of Non-Magnetic Admixtures to the Signal of Electromagnetic Flow Meter

Authors

  • V. Pakenas Kaunas University of Technology
  • J. A. Virbalis Kaunas University of Technology

DOI:

https://doi.org/10.5755/j01.eee.116.10.869

Abstract

The virtual current is formal parameter but its density distribution adequately characterizes the electric properties of the electromagnetic flow meter sensor dependently on the electrodes and channel shape.  By investigating the virtual current distribution in the active zone of electromagnetic flow meter we can obtain the expressions for measurement error which evoke the admixtures with any physical properties and any shape. The obtained expression of measurement error coincides with the results obtained by Bernier and Brennen for flow with the air bubbles. Bibl. 5 (in English; abstracts in English and Lithuanian).

http://dx.doi.org/10.5755/j01.eee.116.10.869

Downloads

Published

2011-12-06

How to Cite

Pakenas, V., & Virbalis, J. A. (2011). Influence of Non-Magnetic Admixtures to the Signal of Electromagnetic Flow Meter. Elektronika Ir Elektrotechnika, 116(10), 7-10. https://doi.org/10.5755/j01.eee.116.10.869

Issue

Section

ELECTRICAL ENGINEERING