Distribution of Magnetic Field of Linear Induction Motor
Abstract
In this article is investigated the distribution of magnetic field of linear induction motor. The are two models for simulation: three-phase asynchronous linear motor and single-phase linear capacitor motor. Simulations results of asynchronous LIM at different instants of time and at different widths of air gap are presented. The are given results of simulation, which show the change of magnetic flux at different instants of time of linear capacitor motor how magnetic field varies at different instants of time and at different current shits in phases. Charts of magnetic flux density below ending and middle tooth of inductor, and magnetic flux density in different cross-sections of air gap are compared. Ill. 9, bibl. 5 (in English; summaries in English, Russian and Lithuanian).
Downloads
Published
How to Cite
Issue
Section
License
The copyright for the paper in this journal is retained by the author(s) with the first publication right granted to the journal. The authors agree to the Creative Commons Attribution 4.0 (CC BY 4.0) agreement under which the paper in the Journal is licensed.
By virtue of their appearance in this open access journal, papers are free to use with proper attribution in educational and other non-commercial settings with an acknowledgement of the initial publication in the journal.