The Selection of Thermistors for the Temperature Measurement Gear
DOI:
https://doi.org/10.5755/j01.eee.111.5.357Abstract
The parameters represented on manufacturer datasheet are usually insufficient for the optimum selection of thermistors. Some manufacturers give generalized numerical data of R(T) dependences. Using this data it is possible to select successfully the most suitable thermistor and equation for describing of T(R) dependence. It is shown that by selecting four points in the generalized characteristic it is possible to calculate the coefficients of the approximation equation. By the application of these coefficients in the calculations the temperature measurement errors can be decreased by an order. The results of calculations and experiment are given. Ill. 4, bibl. 8, tabl. 5 (in English; abstracts in English and Lithuanian).Downloads
Published
2011-06-08
How to Cite
Leskauskaite, J., & Dumcius, A. (2011). The Selection of Thermistors for the Temperature Measurement Gear. Elektronika Ir Elektrotechnika, 111(5), 59-62. https://doi.org/10.5755/j01.eee.111.5.357
Issue
Section
ELECTRONICS
License
The copyright for the paper in this journal is retained by the author(s) with the first publication right granted to the journal. The authors agree to the Creative Commons Attribution 4.0 (CC BY 4.0) agreement under which the paper in the Journal is licensed.
By virtue of their appearance in this open access journal, papers are free to use with proper attribution in educational and other non-commercial settings with an acknowledgement of the initial publication in the journal.