Critical Slip and Maximum Power of Asynchronous Motor Supplied from Limited Power Source and Through Long Cable

Authors

  • S. Gecys
  • E. Milcius

Abstract

There are presented the operating conditions of asynchronous motor supplied from limited power source and through complex circuit. The expressions for critical slip and maximum elektromagnetic power of asynchronous motors evaluating parameters of supply circuit are proposed. These expressions are given using the transform condition of maximum power in electrical circuits.

Published

1998-10-29

How to Cite

Gecys, S., & Milcius, E. (1998). Critical Slip and Maximum Power of Asynchronous Motor Supplied from Limited Power Source and Through Long Cable. Elektronika Ir Elektrotechnika, 18(5). Retrieved from https://eejournal.ktu.lt/index.php/elt/article/view/16041

Issue

Section

Articles