Operational Regimes of Input Filters
Abstract
In this paper an investigation of the L,C filter at output of the single-phase uncontrolled rectifier is done. Equations describing processes in such a filter and are providing possibility to calculate parameters of elements are obtained. Computer simulation realized for filter accepts a results of mathematical investigation. Calculated parameters of the equipment – the mass of reactor for different operational regimes and current of load are estimated. Is evaluated also an impact of the filter on harmonic distortion of the networks current. Is shown that THD indicator is very close to the figure 0.4 and in very small extent depends on level of reactor’s current pulsation. Ill. 7, bibl. 4 (in English; summaries in Lithuanian, English, Russian).
Downloads
Published
How to Cite
Issue
Section
License
The copyright for the paper in this journal is retained by the author(s) with the first publication right granted to the journal. The authors agree to the Creative Commons Attribution 4.0 (CC BY 4.0) agreement under which the paper in the Journal is licensed.
By virtue of their appearance in this open access journal, papers are free to use with proper attribution in educational and other non-commercial settings with an acknowledgement of the initial publication in the journal.