Critical Slip and Maximum Power of Asynchronous Motor Supplied from Limited Power Source and Through Long Cable

S. Gecys, E. Milcius

Abstract


There are presented the operating conditions of asynchronous motor supplied from limited power source and through complex circuit. The expressions for critical slip and maximum elektromagnetic power of asynchronous motors evaluating parameters of supply circuit are proposed. These expressions are given using the transform condition of maximum power in electrical circuits.