The Secondary Element Parameters of Linear Induction Motor

  • E. Matkevičius Vilnius Gediminas Technical University

Abstract

The article analyses two-sided flat linear induction motor with wide secondary element. Soliutions of magnetic field in the air gap between two inductors (in the second zone) and out of that bondaries (in the third zone) are abtained. The appearent power of the secondary, densities of currents, resistances and reactances are calculated. The abtained analytical expressions of secondary element resistance and reactance can be applied in calculations parameters of linear induction motor and modelling of automatic systems of electric drives. Ill.1, bibl. 7 (in Lithuanian; summaries in Lithuanian, English, Russian).

Published
2005-07-22
How to Cite
Matkevičius, E. (2005). The Secondary Element Parameters of Linear Induction Motor. Elektronika Ir Elektrotechnika, 62(6), 68-71. Retrieved from http://eejournal.ktu.lt/index.php/elt/article/view/10474
Section
T 190 ELECTRICAL ENGINEERING